Find on this site:

Double column vertical turnstile
Manual type, double column, vertical turnstile, dual-directional entry, top LCD indicator, working by hand push.
Model # : ACC-2014
Overview
Features
Functions
Installation
Cautions
Certification
ACC-2014 ( square edge & back cover )
Double column vertical turnstile widely applied to shopping mall, railway station, subway, pedestrian passage etc.
Thank you for your interest in our double column vertical turnstile. You can see more information about features, functions, installation, cautions.
Features:
Dimensions: 400x990x380mm
Packaging weight: 30-35Kg
Material:1.5mm 304# stainless steel , brushed finishing or polished( mirror surface )
Power input: AC220V 50Hz or AC110V 50-60Hz
Main board power input: 12VAC & 18VAC
Electromotor power consumption: 24VDC
Electromagnetic power consumption: 24VDC
Other circuit board power consumption: 12VDC
Working temperature:-30℃-60℃/-22℉- +140℉
Working humidity: 5-95%
Length of arm: default 600mm (max 900m)
RS485 ports
Dimensions: 400x990x380mm
Packaging weight: 30-35Kg
Material:1.5mm 304# stainless steel , brushed finishing or polished( mirror surface )
Power input: AC220V 50Hz or AC110V 50-60Hz
Main board power input: 12VAC & 18VAC
Electromotor power consumption: 24VDC
Electromagnetic power consumption: 24VDC
Other circuit board power consumption: 12VDC
Working temperature:-30℃-60℃/-22℉- +140℉
Working humidity: 5-95%
Length of arm: default 600mm (max 900m)
RS485 ports
Functions:
1. Top LCD indicator.
2. Bi-directional function( could enter from both end ).
1. Top LCD indicator.
2. Bi-directional function( could enter from both end ).
Installation steps:
1. Connect with 220VAC.
2. Connect with Left-open, Right-open, Com three ports.
1. Connect with 220VAC.
2. Connect with Left-open, Right-open, Com three ports.
Cautions:
1. Unless permission from manufacturer, the liability of equipment would be guaranteed subject to no peripherals connection and mechanical wear well grounded protected.
2. when the facility is installed outside, please make sure a concrete base foot of 200 mm height for anti-humidity, furthermore, a shelf should be overhead constructed for anti-sunshine. Naked installation in the open environment is strictly forbidden.
1. Unless permission from manufacturer, the liability of equipment would be guaranteed subject to no peripherals connection and mechanical wear well grounded protected.
2. when the facility is installed outside, please make sure a concrete base foot of 200 mm height for anti-humidity, furthermore, a shelf should be overhead constructed for anti-sunshine. Naked installation in the open environment is strictly forbidden.